CE Approved NYY Cable Manufacturer

Engineered for diverse electrical installations and tested to conform to the CE safety standards. Honest, your reliable NYY cable manufacturer in China, with a 100% quality guarantee.

NYY Cable

Honest NYY cables are carefully engineered for different electrical installations, from open air, submerged water to underground. The NYY marks on our cables stand for copper conductors (N), PVC inner insulation (Y), and PVC outer sheath (Y).

At honest, we offer two variants of NYY cables – NYY-J, where J stands for earth or ground conductor, and NYY-O, where O stands for without earth wire. For electrical installations requiring a ground wire, you can choose Honest NYY-J.

The voltage rating for Honest NYY cables ranges from 600 to 1000 volts. While the working temperature varies from -15°C to +70°C in fixed installations and -50°C to +50°C for bent installations.

For NYY cables specifications, Honest maintains a unique cable structure: solid or stranded copper conductors insulated with PVC, followed by filler and a PVC sheath. You can choose from 2 to 5 cores, with cable sizes varying from 1.5 to 630 mm².  

Our cables are tested to conform to DIN VDE 0295, BS 6360, BS 7671, and IEC 60228 requirements. You can use Honest NYY cables in industrial and distribution boards’ electrical installations.

Partner with Honest today and get competitive NYY cable prices – send an inquiry now.

What Is NYY Cable? Design, Use Cases, and NYY-J vs NYY-O Explained

In power engineering and construction projects, NYY cable is a popular basic type of power cable. In this article, we will focus on NYY cable, explaining the meaning of its name, applicable standards, and scope of application. So that you can easily establish a judgment on the cable’s selection, to minimize the risk that could occur with the project due to a misconception.

What Is NYY CableNYY Cable

NYY cable is a low-voltage power cable that uses the VDE standard of Germany and is mainly designed for fixed power transmission. Being widely applied for power distribution in buildings, industrial installations, outdoor, and underground circuits. And it is also used frequently in Europe and projects applied by the European Standard System.

It can be used in these applications because NYY is not designed for temporary power supply or frequent movement, but for long-term fixed laying. It is more rigid and malleable with the environment compared to ordinary building wire, which is able to cope with humidity, outdoor exposure, or underground installation.

NYY Cable Naming Meaning

The name NYY comes from the German cable naming system and is a “quick identification label”. In other words, the three letters would tell engineers which class the cable falls into without needing to read the details.

  • N means that it is a standard power cable according to the VDE system and uses copper conductors.
  • The first Y means that the conductor is insulated with thermoplastic insulation, usually PVC.
  • The second Y means that the cable has a separate outer jacket, also made of PVC.

When you see NYY, you know that it is a fully constructed power cable with an outer jacket for a low-voltage power supply.

Applicable Standards and Certifications

VDE and IEC Standards for NYY Cable

The central basis for the NYY cables is the VDE 0276, defining construction, test methods, and conditions of use of the cables, hence bases for determining compliance in Germany and many European projects.

For international projects, it normally also meets the IEC 60502-1 standard, which is a common specification for low-voltage power cables. Compliance with a single standard means the NYY is recognized and hence used for international projects rather than confined to Germany.

Flame Retardant and Compliance Requirements

Concerning their safety, NYY cables meet the requirements of the flame retardancy standard IEC 60332-1, testing the burning rate of a single cable when exposed to an open flame. It is one of the major reasons why it applies to public buildings and projects.

NYY Cable Construction and Materials

Copper Conductor

The conductor of NYY cables is made of high-purity copper, either a single solid or a multi-stranded copper wire. Solid conductors have a simple structure and are good for small cross-sectional area lines; stranded conductors are softer and are good for large cross-sectional area cables. The copper conductor has good electrical conductivity for stable power transmission with the least possible heat losses.

PVC Insulation

NYY cables have a layer of polyvinyl chloride (PVC) insulation on the outside of each conductor, which keeps the conductors separate and eliminates the possibility of short-circuiting or leakage of electricity. The PVC insulation is flame-retardant and will slow the propagation of fire even in the case of a short circuit or localized heat generation. The color of insulation also helps identify the different cores and makes construction easier.

PVC Outer Sheath

The conductor and insulation are covered by a PVC sheath, which acts as a “protective shell”. It protects the cable from mechanical damage and is also waterproof, resistant to the sun, and certain chemical exposures. If the cable is buried underground or used outside, the casing maintains the cable in its original condition with minimal chances of failure.

Overall, NYY cables have a copper core for current transmission, PVC insulation for electrical safety, and an outer jacket for environmental compatibility. This design allows the cables to be used directly in fixed power lines without the need for additional protective coverings.

Electrical and Mechanical Specifications

Voltage Rating

NYY cables are rated at 600/1000V for low-voltage power lines.

Temperature Range

The operating temperature of NYY cables depends on the installation environment:

  • Fixed installation (no cable movement or vibration): -15°C to +70°C
  • Mobile use: for -5°C to +50°C

When purchasing a cable, this temperature range assists you in deciding whether the cable is capable of dealing with temperature variations, which might be low in winter or high in summer.

Bending Radius

NYY cables need to be bent with a certain radius: 15 times the diameter.

If the bend is too sharp, the conductors may be damaged or the insulation cracked. This requirement is important for construction, especially in conduits, corners, or at equipment access points.

Available Sizes and Core Numbers

NYY cables are available in a wide range of cross-sectional areas and core counts:

  • Cross-sectional areas from 1.5mm² to 630mm².
  • Number of cores: single, 2, 3, 4, 5, also multi-core or stranded conductors

The right size can be selected according to your project’s current-carrying capacity and power supply requirements. For example, 1.5-6mm² for small lighting branch circuits, 16-95mm² for medium-sized power lines, and 120-500mm² for large trunk cables.

Types of NYY Cable (NYY-J vs NYY-O)NYY Cable (6)

NYY-J Cable

NYY-J cable with yellow-green color ground wire, also called protective conductor. It directs leakage current and ensures safety in the event of equipment or system failure.

This cable is used in power distribution trunks, power branch circuits, and projects that require reliable grounding protection. Even when laid outdoors or underground, grounding cables provide additional safety.

NYY-O Cable

NYY-O cables do not have a grounding wire and are primarily intended for use with some control circuits or conditions where independent grounding is not needed. Examples are small light circuits or some industrial control circuits.

Using NYY-O requires you to ensure that the installation environment allows no additional grounding protection; otherwise, you have to cooperate with other safety measures.

Applications of NYY Cable

Power Generation and Distribution

NYY cable can also be used as the primary power supply cable in a power station or a distribution station. It ensures a constant flow of power from the transformer or distribution box to the site of the installation or building.

Underground and Outdoor Installations

NYY cables can be buried directly in the ground or laid outdoors. Its PVC outer jacket protects the cable from moisture, sunlight, and minor mechanical damage, so there is no need for additional pipe protection.

Buildings and Public Infrastructure

In public projects such as schools, hospitals, and commercial buildings, NYY cable’s flame-retardant properties reduce the risk of fire.

Industrial Facilities

In industrial environments, NYY cables power a wide range of equipment and automation systems. Whether on the factory floor, in warehouses and logistics, or in large machinery, it provides a stable current and is resistant to dust, mild chemical environments, and temperature variations.

NYY Cable Installation Notes and Limitations

NYY cables are used in fixed wiring, and there are a number of important points to be kept in mind during your planning and execution stages.

  • NYY cable is not to be used in an area where it can be subject to frequent movement and vibrations. If you use them in an area where it is prone to frequent motion in the form of bending or dragging, it can be expected to have a shorter life.
  • For underground and concrete environments, it is recommended to lay the NYY cable in areas that do not have constant pressure or shock. It is advised to avoid direct contact of sharp stones with the cable sheath during backfilling to avoid the risk of damage. In complex environments, it would be more secure to use simple mechanical protection.
  • When the cable is installed outside, the route taken by the cable should be as fixed as possible to prevent it from being suspended or swaying for an extended period. Although the outer sheath of the cable is weatherproof, a stable installation can significantly reduce the risk of failure.

In general, NYY cables can supply power well if they are laid correctly, and if the operating conditions are too variable or the mechanical load is too high, you may have to reassess the use of a different type of cable.NYY Cable (5)

FAQ

Can the NYY Cable Be Directly Buried?

Yes. The NYY cable is completely encased in a PVC jacket and is usually laid in an underground fixed installation. It can be laid underground directly if there is no mechanical damage and a reasonable backfill is present.

NYY vs NYM Cable: What’s the Difference?

NYY and NYM are both common types of European standard cables, but they are rated to be used in different conditions. NYM cables are meant to be used in indoor fixed wiring and are rated to be used in in-wall or dry environments, whereas NYY cables have a tougher jacket that allows their use in outdoor and wet conditions. However, if the wire has to be buried or kept outside for a long time, then NYY wire is a better choice.

What Affects The Current Carrying Capacity (Ampacity) of NYY Cables?

The rating of the current-carrying capacity of the NYY cables is not fixed or certain; it is determined either by calculation or from tables according to international standards, such as IEC 60364-52. The major factors that determine the current-carrying capability of the cables are the conductor’s cross-sectional area (e.g., 10), the conductor material (e.g., copper or aluminum), the manner of laying the cables (e.g., buried, in ducts, or in air), and the temperature.

How Do I Recognize Quality NYY Cables And Common Quality Defects?

You can focus on three points to identify quality NYY cables: conductor, insulation/sheath, and marking. High-quality products use high-purity oxygen-free copper, with conductors of uniform luster and low resistivity; insulation and jacket PVC are uniformly thick and thin, flexible and elastic, with no pungent odor, and are printed with clear, scrub-resistant model numbers (e.g., NYY-J), specifications, standard numbers, and manufacturer’s logos.

Common quality defects include the use of copper-clad aluminum conductors (lightweight and high resistance), uneven thickness of insulation, brittle and hard sheath materials that are prone to cracking, and blurred or missing markings, all of which can greatly affect safety and service life.

What Are The Main Factors That Determine The Price of NYY Cables?

Generally, the main factors influencing NYY cables’ price are the conductor material or cost, cross-sectional area, quality, and the level of standardization or certification.

Of these, the fluctuation of copper prices on the international market is the biggest variable affecting the cost of the conductor. The larger the cross-sectional area of the conductor (e.g., 4mm², 10mm²), the more material is used and the higher the price.

Next, the use of high-performance PVC, increasing the thickness and homogeneity of the sheath and meeting stricter international standards (e.g., VDE certification) increase the reliability and cost of the cable, impacting the final proposed price.

Final Thought

In procurement, model selection, cross-sectional area, number of cores, and standards can all affect the outcome of your project. If you need to confirm the fitness of NYY cables for your project, you can contact Honest Cable. We can help you make a quick and clear judgment based on your usage environment and needs, and reduce the risk of selection. Contact us today.

Get an Instant Quote Now