NMD90 Cable
Your trusted CSA-approved cable manufacturer in China. Honest NMD90 cables are CSA FT1 and CSA C22.2 compliant, designed for 300V and 90°C electrical installations.

Honest NMD90 cable is our non-metallic sheathed cable designed for both commercial and residential wiring. The “NMD” stands for non-metallic dry.
Our NMD90 cable complies with the CSA C22.2 No. 48, and it comes in either solid or stranded copper or aluminum conductors. The conductor gauge varies from 14 to 8 AWG, or custom size, according to your request.
We offer both two and three-conductor cores, which are then insulated with heat-resistant PVC. It also has an exposed ground conductor, while the outer jacket is CSA FT1 tested and temperature-resistant PVC material.
Whether in exposed or concealed wiring, the NMD90 working temperature is -25°C to 90°C, with a voltage capacity of 300V.
At Honest, we follow strict NMD90 cable manufacturing and testing processes as stipulated by the CSA C22.2 No. 48 and CSA FT1. We also choose conductors according to the ASTM-B3/B8 standard.
As your certified CSA electrical cable manufacturer in China, with over 20 years of experience in the industry, we customize NMD90 cables according to your request. For flexible MOQs and competitive prices, Honest is your trusted CSA cable manufacturer in China – request a quote now.
A Complete Guide for NMD90 Cable
NMD90 cable is extensively employed in residential and commercial applications in the North American and Canadian markets due to its consistent performance and code-compliant design. This article provides a thorough overview of the structure, standards, and conditions of application of NMD90 cable so that you understand its features easily and select the appropriate cable for your projects.
1. What Is NMD90 Cable
NMD90 is a non-metallic sheathed cable (NMSC) which is often used for concealed cabling in domestic and commercial buildings. It is usually installed behind walls, ceilings, or floors with a thin PVC sheath, which eliminates the need for additional metal conduit protection during installation. The “D” in its designation indicates that it is suitable for dry conditions.
In terms of performance, NMD90 offers excellent thermal stability, cold resistance, and mechanical strength. Its conductors can withstand maximum operating temperatures of 90°C (192°F) and maintain normal performance even when installed under lower temperatures. This makes the cable offer both reliability and safety in day-to-day electrical installations.
With regards to standards and certification, NMD90 complies with the Canadian Electrical Code (CEC) and CSA standards, and is cUL certified for broad North American market acceptance. Its copper conductors also meet AWG gauge and ASTM standards, which provide high conductivity, flexibility, and durability, ensuring long-term durability in multiple wiring applications.
2. Structure of NMD90 Cable

2.1 Conductor
The conductor of NMD90 is made of annealed copper, available in either solid or stranded configurations. The copper material ensures excellent electrical conductivity while providing flexibility for easy installation. Common gauges include AWG 14, AWG 12, and AWG 10, catering to varying current demands in residential and commercial wiring applications. The cable also incorporates a bare ground conductor internally, further enhancing safety during use.
2.2 Insulation
Each conductor is encased in PVC insulation rated for temperatures up to 90°C. This insulation material not only possesses high electrical strength but also offers flame-retardant properties and durability, effectively reducing the risk of electrical faults during long-term use. Its heat and weather resistance ensure the installed cable maintains stable performance across diverse environmental conditions.
2.3 Outer Jacket
Its outer jacket is flexible and light-weight non-metallic PVC, easily routed and installed in concealed spaces during construction. The jacket comes in various colors, such as orange, yellow, and white, with each color typically suggesting a different wire gauge or application condition. This color coding makes it easier for electricians to identify cables upon installation, hence minimizing mistakes rapidly.
3. Advantages & Limitations
3.1 Advantages
NMD90 cable offers multiple advantages that make it a popular choice for residential and light commercial wiring. First, it is lightweight and easy to install. Without metal armor, the cable is more flexible, making it easier to pull through conduits and bend during construction, which reduces installation time
Second, it offers a relatively low cost, making it more economical than MC or AC90 cables and highly suitable for large-scale residential projects. Additionally, NMD90 strictly complies with CSA and CEC standards, ensuring safe installation and engineering acceptance.
3.2 Limitations
Although the NMD90 is of excellent advantage, it also has certain limitations. It is only applicable for indoor dry environments and not for outdoor, underground, or humid conditions. Because it does not have metal armor, it has low mechanical protection and can offer less resistance to physical impact. Therefore, it should be installed in concealed areas such as walls and ceilings.
For industrial or harsh-environment projects, heavier-grade cables like AC90, MC Cable, or TECK90 are typically required to ensure safety and durability.
4. Colour Coding of NMD90 Cable
The jacket colors of NMD90 cables are typically used to distinguish different wire gauges and application types, facilitating quick identification in residential wiring:
- White: Frequently used for general residential wiring rated at 15 amps or 20 amps, including 14/2 and 12/2 AWG sizes.
- Red: Used for 208V–240V circuits, containing black and red conductors without a neutral wire.
- Orange: 10 AWG standard residential wiring cable.
- Yellow: 12 AWG, suitable for 15-amp AFCI circuits and 20-amp kitchen GFCI circuits.
- Blue: 14 AWG, includes black and white conductors, commonly used for 120V arc-fault protected receptacle circuits.
5. Applications of NMD90 Cable

5.1 Residential and Commercial Buildings
NMD90 cables are widely used in residential and commercial building electrical installations of all kinds. They can be used for indoor lighting, wiring outlets and switches, and can even be used to provide stable power to office equipment like computers and printers. Due to the cable’s flexibility and ease of concealed installation, hidden wiring can be obtained quickly during the construction of buildings to meet daily use requirements.
5.2 Light Industrial Facilities
NMD90 is utilized in light industrial units as much for power cabling within miniature workshops and production areas. It continuously delivers power to light-duty equipment while offering flexible installation, perfect for tight spaces or installations requiring flexibility.
6. Conclusion
Through this article, you now have a clear understanding of the structure, advantages, applications, and color coding of NMD90 cables, enabling you to more efficiently select the appropriate NMD90 products for residential, commercial, or light industrial projects. If you’re seeking a stable, safe, and North American standard-compliant cable solution, Honestcable offers a full range of premium NMD90 cables, ensuring smoother project construction and greater peace of mind during use.
Typically, NMD90 cable does not require installation within conduit. It is specifically designed for concealed wiring in residential and commercial buildings, allowing direct installation within wall, ceiling, or floor structures. Its PVC jacket provides fundamental mechanical protection and complies with Canadian Electrical Code (CEC) and CSA requirements.
However, in certain situations, an electrician may choose to use conduit. For instance, placing NMD90 within conduit can enhance safety and durability in areas where the cable might be subject to external damage, or where additional protection and neater wiring are desired. Overall, though, this is not a mandatory requirement and depends on the installation environment and local codes.